for analog UV-sensors with photodiode signal output

Features

  • for use as UV-C monitoring system
    (UV values via green, yellow and red "traffic light" system)
  • can be connected with
    one SiC UV-sensor with photodiode signal
  • manual sensor sensitivity adjustment according to the expected UV output
    (using potentiometer and 110%-indication LED)
  • system status indication with LED:
    - green (>75% UV), yellow (50...75% UV) and red (<50%)
  • system status forwarding:
    - potential free relay contact for UV alarm (<50% UV)

Technical Specification

supply voltage: 230V AC ± 10% /45-65Hz (115V AC and 24V DC on request)
operation temperature: max. 45°C (113°F)
ambient temperature: 0 - 40°C (32 - 104°F)
IP code: IP00
mounting: to be installed in a closed cabinet
dimensions (LxWxD): 75 x 49 x 41 mm (2,94 x 1,92 x 1,61 inch)

ZED UV-Sensors

  • ...with photodiode signal
  •  
  •  

Control Units

  • via relay contacts
  •  
  •